SINUS PRO 3000 E EMERGENCY POWER SUPPLIES
• Rated power (continuous) - 2100 W
• Overload power (instantaneous) - 3000 VA
• Battery voltage - 48V
• Rectifier (charging current) - 10A
• Automatic voltage regulator "AVR" - 140 - 275 VAC
• No-load current (no load) - 0.3A ≤ No-load current ≤ 1.5A
• Acceptable supply voltage range - Switching to battery power supply takes place when the mains voltage is lower than 160 V (+ - 5 V) or higher than 260 V (+ - 5 V)
• The frequency of the supply voltage - 45 Hz ~ 65 Hz
• UPS output voltage frequency - 50 Hz (+ - 0.5 Hz)
• Range of output voltages - Voltage regulator AVR: 204 - 240 V, UPS - battery: 230 V (+ - 3%)
• Overload protection (battery powered) - In the event of a 110% - 130% overload, the power is disconnected after 30 seconds. If the overload is greater than 130%, the power is disconnected immediately.
• Overload protection (mains supply) - The device warns of overload until the fuses trip.
• Permissible humidity - 10% RH ~ 90% RH
• Permissible operating temperature - 0 ~ 40 ° C
• Dimensions - 350 mm x 220 mm x 250 mm
• Weight - 17 Kg
• Overload power (instantaneous) - 3000 VA
• Battery voltage - 48V
• Rectifier (charging current) - 10A
• Automatic voltage regulator "AVR" - 140 - 275 VAC
• No-load current (no load) - 0.3A ≤ No-load current ≤ 1.5A
• Acceptable supply voltage range - Switching to battery power supply takes place when the mains voltage is lower than 160 V (+ - 5 V) or higher than 260 V (+ - 5 V)
• The frequency of the supply voltage - 45 Hz ~ 65 Hz
• UPS output voltage frequency - 50 Hz (+ - 0.5 Hz)
• Range of output voltages - Voltage regulator AVR: 204 - 240 V, UPS - battery: 230 V (+ - 3%)
• Overload protection (battery powered) - In the event of a 110% - 130% overload, the power is disconnected after 30 seconds. If the overload is greater than 130%, the power is disconnected immediately.
• Overload protection (mains supply) - The device warns of overload until the fuses trip.
• Permissible humidity - 10% RH ~ 90% RH
• Permissible operating temperature - 0 ~ 40 ° C
• Dimensions - 350 mm x 220 mm x 250 mm
• Weight - 17 Kg