SINUS PRO 1000 S 12V +MPPT EMERGENCY POWER SUPPLIES
• Total power (instantaneous) - 1000 VA.
• Rated power (continuous) - 700 W
• Cooperation with solar panels - Yes (built-in solar controller)
• Solar Controller - 40 A MPPT | ~ 36 V 12 - 50 V
• Voltage stabilizer AVR - Yes | 140 - 275 VAC
• Charging current (network) - 20 A
• Charging voltage (network) - 13.8 V ± 0.5 V | BUILT-IN CHARGER SWITCH
• Built-in rechargeable battery - No.
• Battery voltage - 12V DC
• Cooling - radiators + fans
• Working temperature - 0-40 degrees C
• Dimensions [mm] - 285x140x355
• Weight [kg] - 10.3
• Acceptable supply voltage range - switching to battery power occurs when the mains voltage is below 160 V (+ - 5 V) or above 260 V (+ - 5 V).
• Frequency of supply voltage - 45 Hz ~ 65 Hz.
• Output voltage range - Voltage regulator: 204 - 240 V, UPS: 230 V (+ - 3%)
• UPS output voltage frequency - 50 Hz (+ - 0.5 Hz)
• Overload protection (battery powered) - In case of 110% - 130% overload, the power is cut off after 30 seconds. If the overload exceeds 130%, the power is cut off immediately.
• Overload protection (mains supply) - the device warns of an overload before the fuses blow.
• Allowable humidity - 10% ~ 90%
• Rated power (continuous) - 700 W
• Cooperation with solar panels - Yes (built-in solar controller)
• Solar Controller - 40 A MPPT | ~ 36 V 12 - 50 V
• Voltage stabilizer AVR - Yes | 140 - 275 VAC
• Charging current (network) - 20 A
• Charging voltage (network) - 13.8 V ± 0.5 V | BUILT-IN CHARGER SWITCH
• Built-in rechargeable battery - No.
• Battery voltage - 12V DC
• Cooling - radiators + fans
• Working temperature - 0-40 degrees C
• Dimensions [mm] - 285x140x355
• Weight [kg] - 10.3
• Acceptable supply voltage range - switching to battery power occurs when the mains voltage is below 160 V (+ - 5 V) or above 260 V (+ - 5 V).
• Frequency of supply voltage - 45 Hz ~ 65 Hz.
• Output voltage range - Voltage regulator: 204 - 240 V, UPS: 230 V (+ - 3%)
• UPS output voltage frequency - 50 Hz (+ - 0.5 Hz)
• Overload protection (battery powered) - In case of 110% - 130% overload, the power is cut off after 30 seconds. If the overload exceeds 130%, the power is cut off immediately.
• Overload protection (mains supply) - the device warns of an overload before the fuses blow.
• Allowable humidity - 10% ~ 90%