CCTV
- Ready-made CCTV kits
- HD SDI
- IP Systems
- AHD CCTV
- TVI CCTV
- CVI CCTV
- Video surveillance for transport
- Storage devices
- Portable video cameras
- Thermal, Thermal imaging sights
- Enclosures for CCTV recorders
- Cameras
- Lenses
- Brackets and Housings
- Monitors
- Devices for video transsmision, CONVERTER
- Power supply, UPS
- Pan/Tilt Scanner
- IR+LED illuminators
- cables
- anti surge protection
- silicagel
- Microphones
- Connectors
- Архив
- Alarm systems
- Access control
- Intercom systems
- Fire safety systems
- Videodoorphones, doorphones and intercoms
- Electric gate automation systems and barriers
- Networking
- Sound systems
- Switching and Server Cabinets, accessories
- Tools and accessories
- Cables covers and accessories
- Power supply and accumulators
- HDMI
- Accessories for caravans and campers
- Wiring
- Solar energy
- Wind energy
- Contacts
EMERGENCY POWER SUPPLY SINUS PRO 1500 E 12V
• Rated power (continuous): 1000 W
• Overload power (instantaneous): 1500 VA
• Battery voltage: 12 V
• Rectifier (charging current): 20 A
• Automatic mains voltage regulator - AVR: 140 - 275 VAC
• No-load current (no load): 0.3 A ≤ No-load current ≤ 1.5 A
• Acceptable range of supply voltage: Switching to battery supply takes place when the mains voltage is lower than 160 V (+ - 5 V) or higher than 260 V (+ - 5 V)
• Mains frequency: 45 Hz ~ 65 Hz
• UPS output voltage frequency: 50 Hz (+ - 0.5 Hz)
• Range of output voltages: Voltage regulator AVR: 204 - 240 V, UPS - battery: 230 V (+ - 3%)
• Overload protection (battery powered): In the event of an overload of 110% - 130%, the power is disconnected after 30 seconds. If the overload is higher than 130%, the power is disconnected immediately.
• Overload protection (mains supply): The device gives an overload warning until the fuses trip.
• Operating humidity: 10% RH ~ 90% RH
• Permissible operating temperature: 0 ~ 40 ° C
• Dimensions: 350 mm x 220 mm x 250 mm
• Weight: 14 Kg
• Overload power (instantaneous): 1500 VA
• Battery voltage: 12 V
• Rectifier (charging current): 20 A
• Automatic mains voltage regulator - AVR: 140 - 275 VAC
• No-load current (no load): 0.3 A ≤ No-load current ≤ 1.5 A
• Acceptable range of supply voltage: Switching to battery supply takes place when the mains voltage is lower than 160 V (+ - 5 V) or higher than 260 V (+ - 5 V)
• Mains frequency: 45 Hz ~ 65 Hz
• UPS output voltage frequency: 50 Hz (+ - 0.5 Hz)
• Range of output voltages: Voltage regulator AVR: 204 - 240 V, UPS - battery: 230 V (+ - 3%)
• Overload protection (battery powered): In the event of an overload of 110% - 130%, the power is disconnected after 30 seconds. If the overload is higher than 130%, the power is disconnected immediately.
• Overload protection (mains supply): The device gives an overload warning until the fuses trip.
• Operating humidity: 10% RH ~ 90% RH
• Permissible operating temperature: 0 ~ 40 ° C
• Dimensions: 350 mm x 220 mm x 250 mm
• Weight: 14 Kg