CCTV
- Ready-made CCTV kits
- HD SDI
- IP Systems
- AHD CCTV
- TVI CCTV
- CVI CCTV
- Video surveillance for transport
- Storage devices
- Portable video cameras
- Thermal, Thermal imaging sights
- Enclosures for CCTV recorders
- Cameras
- Lenses
- Brackets and Housings
- Monitors
- Devices for video transsmision, CONVERTER
- Power supply, UPS
- Pan/Tilt Scanner
- IR+LED illuminators
- cables
- anti surge protection
- silicagel
- Microphones
- Connectors
- Архив
- Alarm systems
- Access control
- Intercom systems
- Fire safety systems
- Videodoorphones, doorphones and intercoms
- Electric gate automation systems and barriers
- Networking
- Sound systems
- Switching and Server Cabinets, accessories
- Tools and accessories
- Cables covers and accessories
- Power supply and accumulators
- HDMI
- Accessories for caravans and campers
- Wiring
- Solar energy
- Wind energy
- Contacts
EMERGENCY POWER SUPPLIES SINUS UPS 800 + 55AH 12V
• Battery life: 5-8 years
• Total power (instantaneous): 800 VA
• Rated power (continuous): 500 W
• AVR voltage stabilizer: Yes | 140 - 275 VAC
• Charging current (mains): 5 A
• Charging voltage (mains): 13.8V ± 0.5V
• Built-in battery: AGM 12V - 55 Ah
• Battery voltage (s): 12 VDC
• Cooling: heat sinks + fans
• Working temperature: 0-40 degrees Celsius
• Dimensions: 280x380x180 mm
• Weight: 26 kg
• Acceptable supply voltage range - Switching to battery power supply takes place when the mains voltage is lower than 160 V (+ - 5 V) or higher than 260 V (+ - 5 V)
• Mains frequency: 45 Hz ~ 65 Hz
• Range of output voltages: - Mains voltage regulator: 204 - 240 V, UPS: 230 V (+ - 3%)
• UPS output voltage frequency: 50 Hz (+ - 0.5 Hz)
• Overload protection (battery power supply): - In the event of 110% - 130% overload, the power is disconnected after 30 seconds. If the overload is higher than 130%, the power supply is disconnected immediately.
• Overload protection (mains supply): - The device warns of overloading until the fuses trip.
• Operating humidity: 10% RH ~ 90% RH
• Total power (instantaneous): 800 VA
• Rated power (continuous): 500 W
• AVR voltage stabilizer: Yes | 140 - 275 VAC
• Charging current (mains): 5 A
• Charging voltage (mains): 13.8V ± 0.5V
• Built-in battery: AGM 12V - 55 Ah
• Battery voltage (s): 12 VDC
• Cooling: heat sinks + fans
• Working temperature: 0-40 degrees Celsius
• Dimensions: 280x380x180 mm
• Weight: 26 kg
• Acceptable supply voltage range - Switching to battery power supply takes place when the mains voltage is lower than 160 V (+ - 5 V) or higher than 260 V (+ - 5 V)
• Mains frequency: 45 Hz ~ 65 Hz
• Range of output voltages: - Mains voltage regulator: 204 - 240 V, UPS: 230 V (+ - 3%)
• UPS output voltage frequency: 50 Hz (+ - 0.5 Hz)
• Overload protection (battery power supply): - In the event of 110% - 130% overload, the power is disconnected after 30 seconds. If the overload is higher than 130%, the power supply is disconnected immediately.
• Overload protection (mains supply): - The device warns of overloading until the fuses trip.
• Operating humidity: 10% RH ~ 90% RH