- Videonovērošana
-
Apsardzes signalizācija
- Mini Alarms
- Bezvadu apsardzes sistēmas
- GSM
- Signalizācijas paneļi
- Kustības detektori PIR
- Kombinētie detektori PIR+MW
- Stikla plīšanas GBD
- Magnētiskie kontakti
- Vibro detektori
- Ūdens applūdes sensors
- Gāzes detektori
- Temperatūras detektori
- Ugunsdzēsības detektori
- Perimetra apsardze
- Trauksmes pogas
- Aksesuāri
- Sirēnas un stroblampas
- Signalizācijas kabeļi
- Kontroles sistēmas
- Sarunu sistēmas
- Ugunsdzēsības sistēmas
- Audio un Video domofoni
- Automātika vārtiem un barjeras
- Tīkla iekārtas
- Apskaņošanas sistēmas
- Kommutācijas un Serveru skapji, piederumi
- Instrumenti
- Kabeļi,aizsegi,caurules un piederumi
- Barošanas bloki,transformatori un akumulātori
- HDMI
- Piekabju un kemperu piederumi
- Elektromontāža
- Saules enerģija
- Vēja enerģija
- Kontakti
NON-SE - Forteza Tribo vibrāciju nejūtīgs kabelis
Non sensitive elements (NON-SE) intended: to connect TRIBO-S processing unit with sensitive element; pass the gates or building in the line with fence; arrange special detection zone for the best integration of TRIBO-S with CCTV system.
PURPOSE
Non sensitive element is a part of the TRIBO-S fence protection system which is
not sensitive for deformation and vibration. It is using to transmit signals
between TRIBO-S unit and sensitive element or connect SE-86 with SE-86 using
connection sleeves.
GENERAL INFORMATION
Non sensitive element max. length in one input channel of TRIBO-S processing
unit is 300 meters, it can be interchange with SE-86 to NON-SE to SE-86.
Non sensitive elements isolation is not protected from the outside weather
conditions so the element must be protected with plastic corrugated tube when
mounted on the fence or underground.
LAYING OF NON SENSITIVE ELEMENT
TRIBO-S processing unit installation near the fence.
Variant
where TRIBO-S processing unit installed near the fence (in security
room) at distance from the protected fence were sensitive elements is
mounted. In this variant with one TRIBO-S processing unit we can protect
up to 600 meters of the fence. The maximum length of sensitive element
and non-sensitive for one detection zone is SE-86 300 meters NON-SE 300
meters.
Requirement for TRIBO-S system „one detection zone up to 50 meters“ for integration with CCTV system.
Variant where requirement for TRIBO-S system to give alarms in different detection zones lengths. Detection zone can be from 1 meter up to 300 meters. Below you see the drawing were requirement was to have alarm from detection zone 50 meters, 2 lines of sensitive element it is standard for 2 meters high fence.
Using NON-SE element to pass gates and buildings.
Variant where in detections zone is a gates and buildings. Using connection sleeves and non-sensitive element we can arrange the non-sensitive gaps in detection zone. In this option we use connection sleeve to connect SE-86 with NON-SE, using the protection pipe lay the NON-SE element under the entries road and using the connection sleeve connect NON-SE with SE-86 on the fence. So the same detection zone before gate and after. For gate protection we offer to use FMC 10 (50) or FMC 24 (50).