- CCTV
- Alarm systems
- Access control
- Intercom systems
- Fire safety systems
- Videodoorphones, doorphones and intercoms
- Electric gate automation systems and barriers
- Networking
- Sound systems
- Switching and Server Cabinets, accessories
- Tools and accessories
- Cables covers and accessories
- Power supply and accumulators
- HDMI
- Accessories for caravans and campers
- Wiring
- Solar energy
- Wind energy
- Contacts
EA630 - UPS 3000VA / 2400W, Recharge time 6-8 h, Rack-mount 3U
• Output power factor 0.8
• DSP digital control
• Boost and buck AVR for voltage stabilization
• Auto sensing frequency
• Adjustable charging current and battery shutdown point Settable
• ECO mode and no-load shutdown
• Humanized alarm system
• Power-on self test Cold start
• Auto restart when mains power is restored
• Intelligent battery management
• Short circuit and overload protection
• Automatic charging in OFF mode
• USB & RJ45, AS400 / SNMP (optional) communication port
CAPACITY |
|
Reactive Power (VA) |
3000 |
Active Power (W) |
2400 |
DC INPUT |
|
Rated voltage |
48V |
DC input range (default) |
40 ~ 60 V |
AC INPUT |
|
AC input range (bypass mode) |
0 ~ 121 V / 132 V / 138 V / 144 Vac for 100 V / 110 V / 115 V / 120 Vac ± 10 Vac 0 ~ 242 V / 264 V / 276 V / 288 Vac for 200 V / 220 V / 230 V / 240 Vac ± 10 Vac |
AC input range (mains mode) |
100 V: 70 ~ 130 Vac / 110 V: 80 ~ 140 Vac / 115 V: 85 ~ 145 Vac 120 V: 90 ~ 150 Vac / 200 V: 145 ~ 260 Vac / 220 V: 165 ~ 280 Vac 230 V: 175 ~ 290 Vac / 240 V: 185 ~ 300 Vac |
Frequency range |
50 Hz / 60 Hz (auto-sense) 50 Hz / 60 Hz ± 5% ~ 15% |
Generator connection |
Available (generator input power is settable) |
OUTPUT |
|
inverter output range |
100 V / 110 V / 115 V / 120 V / 200 V / 220 V / 230 V / 240 Vac ± 5% (settable) |
AC output range (bypass mode) |
0 ~ 121 V / 132 V / 138 V / 144 Vac for 100 V / 110 V / 115 V / 120 Vac ± 10 Vac 0 ~ 242 V / 264 V / 276 V / 288 Vac for 200 V / 220 V / 230 V / 240 Vac ± 10 Vac |
AC output range (mains mode) |
100 V: 90 ~ 110 Vac / 110 V: 99 ~ 115 Vac / 115 V: 103 ~ 126 Vac 120 V: 108 ~ 132 Vac / 200 V: 166 ~ 226 Vac / 220 V: 188 ~ 245 Vac 230 V: 199 ~ 254 Vac / 240 V: 210 ~ 264 Vac |
Output frequency |
50 / 60 Hz ± 0.3 Hz (settable) |
Waveform |
Pure sine wave |
Inverter efficiency |
Max. 85% |
Energy saving mode |
Settable (< 3% load) , enter in 80 s |
No-load shutdown |
Settable (< 3% load) , enter in 80 s |
Transfer time |
≤ 10 ms |
THDV (resistive load) |
≤ 5% |
Protections |
Overload, short circuit (inverter), battery low voltage, battery overcharge, overtemperature |
Overload (mains mode) |
110% for 120 s, 125% for 60 s, 150% for 10 s (transfer to bypass mode) |
Overload (inverter mode) |
110% for 60 s, 125% for 10 s, 150% for 5 s (shut down directly) |
Mute |
Automatic mute in 60 s or by manual |
BATTERIES |
|
Battery capacity (H: external expansion) |
12 V / 9 Ah x 4 |
Charging current |
Standard model (S): 1 A (default) Long time model (H): 10 A (default); <10 A, set step 1 A; ≥ 10 A, set step 5 A |
Equalizing charge voltage |
Single battery 14.1 Vdc (default), 13.6 ~ 15 Vdc adjustable |
Floating charge voltage |
Single battery 13.5 Vdc(default) 13.2 ~ 14.6 Vdc adjustable |
Low voltage alarm point |
Single battery 10.8 Vdc (default) 9.6 ~ 13 Vdc adjustable |
Low voltage shutdown point |
Single battery 10.2 Vdc (default) 9.6 ~ 11.5 Vdc adjustable |
DIMENSIONS TOWER or CABINET |
|
Net / Gross weight (kg) |
28.1 / 30.2 (S) 28.0 / 30.0 (H) |
Dimensions (W × D × H) (mm) |
190 x 467 x 335.5 (S / H) |
Packaged dimensions (W × D × H) (mm) |
320 x 592 x 462 (S / H) |
DIMENSIONS RACK-MOUNT |
|
Net / Gross weight (kg) |
|